				Furse Earthing and Lightning Protection 
				and Electronic Systems Protection by Thomas & Betts 
				 
				
				RF Systems Using Coaxial 
				Cables at frequencies between DC & 2.7GHz 
				 The 
				standard RF protector offers a cost effective protection 
				solution for use on coaxial cables to protect RF transmitter and 
				receiver systems, including electronics located at the antenna 
				or dish. Typical examples include cell sites, military 
				communications, satellite earth stations and pager systems. 
					- 
					
					Restricts 
					let-through voltage below damage levels of interface 
					circuitry  
					- 
					
					Very low 
					attenuation and near unity VSWR over a wide range of 
					frequencies ensure the protectors do not impair systems 
					performance  
					- 
					
					Wide bandwidth 
					means a single product is suitable for a range of 
					applications, including the transmission of DC power  
					- 
					
					Easily mounted 
					and earthed via fixtures on the base of the unit  
					- 
					
					Available with 
					N, 7/16 DIN and BNC connectors  
					- 
					
					Robust silver 
					plated aluminium housing   
				 
				
				CLICK HERE 
				for more information 
				 
				
				
				Higher Specification RF 
				Systems Using Coaxial Cables at frequencies between 50MHz & 
				2.7GHz 
				 Use 
				on coaxial cables to protect RF transmitter and receiver 
				systems, including electronics located at the antenna or dish. 
				Typical examples include cell sites, military communications, 
				satellite earth stations, pager systems and emergency services 
				communications systems.  
					- 
					
					Very low 
					let-through voltage (enhanced protection to BS EN 62305) 
					between all lines - Full Mode protection  
					- 
					
					Superior 
					transient protection to both Gas Discharge Tube (GDT) and 
					Quarter Wave Stub (QWS) based protectors  
					- 
					
					Full mode design 
					capable of handling partial lightning currents as well as 
					allowing continual operation of protected equipment  
					- 
					
					Wide bandwidth 
					means a single product is suitable for a range of 
					applications  
					- 
					
					Available with 
					N, 7/16 DIN and BNC connectors  
					- 
					
					Easily mounted 
					and earthed via fixtures on the base of the unit that accept 
					M3 and M5 screws or via mounting brackets   
				 
				
				CLICK HERE for 
				more information 
				 
				
				CCTV Video Lines 
				 Use 
				these protectors on the video cable to outdoor CCTV cameras and 
				central control and monitoring equipment. Suitable for coaxial 
				CCTV cables with BNC connectors (ESP CCTV/B) or twisted pair 
				CCTV lines (ESP CCTV/T) on systems with either an earthed or an 
				isolated screen. Not suitable for use on broadcast, satellite or 
				cable TV systems.  
					- 
					
					Very low 
					let-through voltage (enhanced protection to BS EN 62305) 
					between all lines - Full Mode protection  
					- 
					
					Full mode design 
					capable of handling partial lightning currents as well as 
					allowing continual operation of protected equipment  
					- 
					
					100MHz bandwidth 
					prevents the degradation of high frequency signals  
					- 
					
					Low in-line 
					resistance to minimise unnecessary reductions in signal 
					strength and maximise signalling distance  
					- 
					
					Suitable for 
					either earthed or isolated screen systems  
					- 
					
					ESP CCTV/B has 
					Network Rail Approval PA05/02510. NRS PADS reference 
					086/023410  
				 
				
				CLICK HERE 
				for more information 
				 
				
				
				SSI Mains Power Supplies 
				& Data Links 
				 To 
				prevent transient overvoltage damage to Solid State Interlocking 
				(SSI) systems, protectors should be fitted in trackside cabinets 
				and equipment rooms, on both the data link and the mains power 
				lines. 
					- 
					
					Accepted for use 
					on Network Rail infrastructure  
					- 
					
					Very low 
					let-through voltage (enhanced protection to BS EN 62305) 
					between all sets of conductors - Full Mode Protection (ESP 
					SSI/120AC and ESP SSI/140AC) and all signal lines (ESP 
					SSI/M)  
					- 
					
					ESP SSI/B 
					modified base unit can be permanently wired into the system  
					- 
					
					ESP SSI/M 
					plug-in protection module can be replaced without 
					interfering with the operation of the system  
					- 
					
					ESP SSI/B 
					incorporates a 100Ω terminating resistance that can be 
					connected if required  
					- 
					
					ESP SSI/120AC 
					and ESP SSI/140AC are a compact size for easy installation 
					in trackside cabinets and control rooms  
					- 
					
					All products 
					have Network Rail Certificates of Acceptance, allowing them 
					to be used on Network Rail infrastructure   
				 
				
				CLICK HERE 
				for more information 
				 
				
				
				Coaxial TV Systems 
				 Use 
				to protect analogue and digital Cable, Terrestrial and Satellite 
				TV installations. 
					- 
					
					Very low 
					let-through voltage (enhanced protection to BS EN 62305) 
					between all lines - Full Mode protection  
					- 
					
					Low attenuation 
					and high return loss over a wide range of frequencies 
					ensures the protectors do not impair 
					system performance  
					- 
					
					Substantial 
					earth termination  
					- 
					
					Supplied ready 
					for flat mounting  
					- 
					
					Strong metal 
					housing   
				 
				
				CLICK HERE 
				for more information  |