				Furse Earthing and Lightning Protection 
				and Electronic Systems Protection by Thomas & Betts 
				 
				Enhanced Single Phase 
				Supplies for Equipotential Bonding 
				 Use 
				on single phase mains supplies and power distribution systems 
				for protection against partial direct or indirect lightning 
				strikes.  
					- 
					
					Enhanced 
					protection (to BS EN 62305) offering low let-through voltage 
					further minimizing the risk of flashover creating dangerous 
					sparking or electric shock  
					- 
					
					Repeated 
					protection in lightning intense environments  
					- 
					
					The varistor 
					based design eliminates the high follow current (lf) 
					associated with spark gap based surge protection  
					- 
					
					Indicator shows 
					when the protector requires replacement  
					- 
					
					Remote signal 
					contact can indicate the protectors' status through 
					interfacing with a building management system  
					- 
					
					Compact, space 
					saving design  
				 
				
				CLICK HERE 
				for more information 
				 
				
				
				Enhanced Three Phase Supplies 
				for Equipotential Bonding 
				 Use 
				on three phase mains supplies and power distribution systems for 
				protection against partial direct or indirect lightning strikes: 
					- 
					
					Enhanced 
					protection (to BS EN 62305) offering low let-through voltage 
					further minimizing the risk of flashover creating dangerous 
					sparking or electric shock  
					- 
					
					Repeated 
					protection in lightning intense environments  
					- 
					
					The varistor 
					based design eliminates the high follow current (lf) 
					associated with spark gap based surge protection  
					- 
					
					Indicator shows 
					when the protector requires replacement  
					- 
					
					Remote signal 
					contact can indicate the protectors' status through 
					interfacing with a building management system  
					- 
					
					Compact, space 
					saving design  
				 
				
				CLICK HERE 
				for more information 
				 
				
				
				Single Phase Supplies with 
				DIN Housing 
				 Combined 
				Type 1, 2 and 3 tested protector (to BS EN 61643) for use on 
				mains power distribution systems primarily to protect connected 
				electronic equipment from transient overvoltages on the mains 
				supply, e.g. computer, communications or control equipment. 
				Innovative remote display options allow both protector and 
				display to be mounted in their optimum position. 
					- 
					
					Very low 
					let-through voltage (enhanced protection to BS EN 62305) 
					between all sets of conductors (phase to neutral, phase to 
					earth, neutral to earth - Full Mode protection)  
					- 
					
					Full mode design 
					capable of handling partial lightning currents as well as 
					allowing continual operation of protected equipment  
					- 
					
					Three phase ESP 
					XXX D1R/LED or ESP XXX D1R/LCD units (where XXX = 208, or 
					415, or 480) have a remote display that allows the protector 
					to be mounted close to the incoming feed or distribution 
					board with the display being mounted in a visible position 
					e.g. at the front of the panel  
					- 
					
					Three phase ESP 
					XXX D1/LCD or ESP XXX D1R/LCD units have backlit LCD 
					intelligent display offering clear status information that 
					can be rotated should the unit be mounted on its side to 
					facilitate short connection leads for optimal protection  
					- 
					
					Changeover 
					active volt free contact enables the protector to be used to 
					warn of phase loss (i.e. power failure, 
					blown fuses etc)  
					- 
					
					Flashing warning 
					of potentially fatal neutral to earth supply faults (due to 
					incorrect earthing, wiring errors or unbalanced conditions)  
				 
				
				CLICK HERE 
				for more information 
				 
				
				
				Three Phase Extra High 
				Maximum Surge Current Capacity 
				 Use 
				ESP M2 versions on main distribution panel for buildings with a 
				Class III or IV structural LPS fitted or exposed 3 phase power 
				lines where no LPS is fitted. Use ESP M4 versions on main 
				distribution panel for buildings with a Class I or II LPS 
				fitted.  
					- 
					
					Very low let-through voltage 
					between all sets of conductors (phase to neutral, phase to 
					earth and neutral to earth)  
					- 
					
					Full mode design capable of 
					handling high energy partial lightning currents as well as 
					allowing continual operation of protected equipment  
					- 
					
					Innovative multiple thermal 
					disconnect technology, for safe disconnection from faulty or 
					abnormal supplies (without compromising protective 
					performance)  
					- 
					
					Three way visual indication of 
					protection status  
					- 
					
					Advanced pre-failure warning so 
					you need never be unprotected  
					- 
					
					Remote indication facility 
					allows pre-failure warning to be linked to a building 
					management system, buzzer or light  
				 
				
				
				CLICK HERE 
				for more information 
				 
				
				
				Mains Supplies & Power 
				Distribution Systems 
				 Combined 
				Type 1, 2 and 3 tested protector (to BS EN 61643) for use on 
				mains power distribution systems primarily to protect connected 
				electronic equipment from transient overvoltages on the mains 
				supply, e.g. computer, communications or control equipment.  
					- 
					
					Very low 
					let-through voltage (enhanced protection to BS EN 62305) 
					between all sets of conductors (phase to neutral, phase to 
					earth, neutral to earth - Full Mode protection)  
					- 
					
					Provides 
					repeated protection in lightning intense environments  
					- 
					
					Full mode design 
					capable of handling partial lightning currents as well as 
					allowing continual operation of protected equipment  
					- 
					
					Innovative 
					multiple thermal disconnect technology for safe 
					disconnection from faulty of abnormal supplies (without 
					compromising protective performance)  
					- 
					
					Three way visual 
					indication of protection status and advanced pre-failure 
					warning so you need never be unprotected  
					- 
					
					Remote 
					indication facility allows pre-failure warning to be linked 
					to a building management system, buzzer or light  
				 
				
				CLICK HERE 
				for more information 
				 
				
				
				Mains Supplies with Remote 
				Display Indication 
				 Use 
				ESP M1R versions on main distribution panel for buildings with 
				multiple metallic services (e.g. gas, water, telephone lines) 
				and on sub-distribution boards feeding sensitive equipment. Use 
				ESP M2R versions on main distribution panel for buildings with a 
				Class III or IV structural LPS fitted or exposed 3 phase power 
				lines where no LPS is fitted. Use ESP M4R versions on main 
				distribution panel for buildings with a Class I or II LPS 
				fitted.  
					- 
					
					Very low 
					let-through voltage between all sets of conductors (phase to 
					neutral, phase to earth and neutral to earth)  
					- 
					
					Full mode design 
					capable of handling high energy partial lightning currents 
					as well as allowing continual operation of protected 
					equipment  
					- 
					
					Innovative 
					multiple thermal disconnect technology, for safe 
					disconnection from faulty or abnormal supplies (without 
					compromising protective performance)  
					- 
					
					Three way visual 
					indication of protection status  
					- 
					
					Advanced 
					pre-failure warning so you need never be unprotected  
					- 
					
					Remote 
					indication facility allows pre-failure warning to be linked 
					to a building management system, buzzer or light  
				 
				
				CLICK HERE 
				for more information 
				 
				
				
				DC Supplies & Power 
				Distribution Systems 
				 Use 
				on DC power distribution systems to protect connected electronic 
				equipment from transient overvoltages on the DC supply, e.g. DC 
				fed communications or control equipment.  
					- 
					
					Low let-through 
					voltage (enhanced protection to BS EN 62305) between all 
					sets of conductors (positive to negative, positive to earth 
					and negative to earth) - Full Mode protection) allowing 
					continuous operation of equipment  
					- 
					
					Repeated 
					protection in lightning intense environments  
					- 
					
					Advanced 
					pre-failure warning so you need never be unprotected  
					- 
					
					Remote 
					indication facility allows pre-failure warning to be linked 
					to a building management systems, buzzer or light  
					- 
					
					Base provides 
					ultra low inductance earth bond to metal panels  
					- 
					
					Compact size for 
					installation in the power distribution board   
				 
				
				CLICK HERE 
				for more information 
				 
				
				
				Low Current Mains Supplies 
				 Use 
				these protectors on low current mains power supplies, e.g. CCTV 
				cameras, alarm panels and telemetry equipment.  
					- 
					
					Very low 
					let-through voltage (enhanced protection to BS EN 62305) 
					between all sets of conductors (phase to neutral, phase to 
					earth, neutral to earth - Full Mode protection) allowing 
					continuous operation of equipment  
					- 
					
					Provides 
					repeated protection in lightning intense environments  
					- 
					
					Removable DIN 
					rail foot for simple clip-on mounting to top hat DIN rails  
					- 
					
					Colour coded 
					terminals give a quick and easy installation check - grey 
					for the dirty (line) end and green for the clean end  
					- 
					
					Available 
					ready-boxed to IP66 for use in dirty of damp environments 
					(protectors with /BX suffix)  
					- 
					
					Fixing holes 
					ready for flat mounting   
				 
				
				CLICK HERE for 
				more information 
				 
				
				
				Plug-in Equipment 
				 ESP 
				MC series can be used to protect all sorts of plug-in equipment, 
				including hospital laboratory equipment, modems, fax machines 
				and PCs. 
				  
					- 
					
					Low let-through 
					voltage between all sets of conductors  
					- 
					
					Three way visual 
					indication of protection status  
					- 
					
					Protects against 
					radio frequency interference  
					- 
					
					TN and Cat-5e 
					versions can conveniently protect both mains and 
					telecom/data lines in one unit  
					- 
					
					Rugged, heavy 
					duty construction  
					- 
					
					Bracket kit ESP 
					MC/19BK available for rear or 16" rack mounting  
				 
				
				CLICK HERE 
				for more information  |